File:Femtosecond-Laser-Axotomy-in-Caenorhabditis-elegans-and-Collateral-Damage-Assessment-Using-a-pone.0058600.s001.ogv
From Wikimedia Commons, the free media repository
Jump to navigation
Jump to search
No higher resolution available.
Femtosecond-Laser-Axotomy-in-Caenorhabditis-elegans-and-Collateral-Damage-Assessment-Using-a-pone.0058600.s001.ogv (Ogg Theora video file, length 2.9 s, 128 × 128 pixels, 683 kbps, file size: 238 KB)
File information
Structured data
Captions
Summary[edit]
DescriptionFemtosecond-Laser-Axotomy-in-Caenorhabditis-elegans-and-Collateral-Damage-Assessment-Using-a-pone.0058600.s001.ogv |
English: Linear techniques for damage assessment. Axotomy process in C. elegans. LT shows damage to the cuticle, while confocal imaging shows the induced autofluorescence and the retraction of the cut ends of the axon. |
||
Date | |||
Source | Media S1 from Santos S, Mathew M, Olarte O, Psilodimitrakopoulos S, Loza-Alvarez P (2013). "Femtosecond Laser Axotomy in Caenorhabditis elegans and Collateral Damage Assessment Using a Combination of Linear and Nonlinear Imaging Techniques". PLOS ONE. DOI:10.1371/journal.pone.0058600. PMID 23484040. PMC: 3590135. | ||
Author | Santos S, Mathew M, Olarte O, Psilodimitrakopoulos S, Loza-Alvarez P | ||
Permission (Reusing this file) |
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 20:17, 14 March 2013 | 2.9 s, 128 × 128 (238 KB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Transcode status
Update transcode statusMetadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Author | Santos S, Mathew M, Olarte O, Psilodimitrakopoulos S, Loza-Alvarez P |
---|---|
Usage terms | http://creativecommons.org/licenses/by/3.0/ |
Image title | Linear techniques for damage assessment. Axotomy process in C. elegans. LT shows damage to the cuticle, while confocal imaging shows the induced autofluorescence and the retraction of the cut ends of the axon. |
Software used | Xiph.Org libtheora 1.1 20090822 (Thusnelda) |
Date and time of digitizing | 2013 |